245 lines
9.6 KiB
Go
245 lines
9.6 KiB
Go
|
// Copyright 2019 The Go Authors. All rights reserved.
|
||
|
// Use of this source code is governed by a BSD-style
|
||
|
// license that can be found in the LICENSE file.
|
||
|
|
||
|
/*
|
||
|
Package ppc64 implements a PPC64 assembler that assembles Go asm into
|
||
|
the corresponding PPC64 instructions as defined by the Power ISA 3.0B.
|
||
|
|
||
|
This document provides information on how to write code in Go assembler
|
||
|
for PPC64, focusing on the differences between Go and PPC64 assembly language.
|
||
|
It assumes some knowledge of PPC64 assembler. The original implementation of
|
||
|
PPC64 in Go defined many opcodes that are different from PPC64 opcodes, but
|
||
|
updates to the Go assembly language used mnemonics that are mostly similar if not
|
||
|
identical to the PPC64 mneumonics, such as VMX and VSX instructions. Not all detail
|
||
|
is included here; refer to the Power ISA document if interested in more detail.
|
||
|
|
||
|
Starting with Go 1.15 the Go objdump supports the -gnu option, which provides a
|
||
|
side by side view of the Go assembler and the PPC64 assembler output. This is
|
||
|
extremely helpful in determining what final PPC64 assembly is generated from the
|
||
|
corresponding Go assembly.
|
||
|
|
||
|
In the examples below, the Go assembly is on the left, PPC64 assembly on the right.
|
||
|
|
||
|
1. Operand ordering
|
||
|
|
||
|
In Go asm, the last operand (right) is the target operand, but with PPC64 asm,
|
||
|
the first operand (left) is the target. The order of the remaining operands is
|
||
|
not consistent: in general opcodes with 3 operands that perform math or logical
|
||
|
operations have their operands in reverse order. Opcodes for vector instructions
|
||
|
and those with more than 3 operands usually have operands in the same order except
|
||
|
for the target operand, which is first in PPC64 asm and last in Go asm.
|
||
|
|
||
|
Example:
|
||
|
ADD R3, R4, R5 <=> add r5, r4, r3
|
||
|
|
||
|
2. Constant operands
|
||
|
|
||
|
In Go asm, an operand that starts with '$' indicates a constant value. If the
|
||
|
instruction using the constant has an immediate version of the opcode, then an
|
||
|
immediate value is used with the opcode if possible.
|
||
|
|
||
|
Example:
|
||
|
ADD $1, R3, R4 <=> addi r4, r3, 1
|
||
|
|
||
|
3. Opcodes setting condition codes
|
||
|
|
||
|
In PPC64 asm, some instructions other than compares have variations that can set
|
||
|
the condition code where meaningful. This is indicated by adding '.' to the end
|
||
|
of the PPC64 instruction. In Go asm, these instructions have 'CC' at the end of
|
||
|
the opcode. The possible settings of the condition code depend on the instruction.
|
||
|
CR0 is the default for fixed-point instructions; CR1 for floating point; CR6 for
|
||
|
vector instructions.
|
||
|
|
||
|
Example:
|
||
|
ANDCC R3, R4, R5 <=> and. r5, r3, r4 (set CR0)
|
||
|
|
||
|
4. Loads and stores from memory
|
||
|
|
||
|
In Go asm, opcodes starting with 'MOV' indicate a load or store. When the target
|
||
|
is a memory reference, then it is a store; when the target is a register and the
|
||
|
source is a memory reference, then it is a load.
|
||
|
|
||
|
MOV{B,H,W,D} variations identify the size as byte, halfword, word, doubleword.
|
||
|
|
||
|
Adding 'Z' to the opcode for a load indicates zero extend; if omitted it is sign extend.
|
||
|
Adding 'U' to a load or store indicates an update of the base register with the offset.
|
||
|
Adding 'BR' to an opcode indicates byte-reversed load or store, or the order opposite
|
||
|
of the expected endian order. If 'BR' is used then zero extend is assumed.
|
||
|
|
||
|
Memory references n(Ra) indicate the address in Ra + n. When used with an update form
|
||
|
of an opcode, the value in Ra is incremented by n.
|
||
|
|
||
|
Memory references (Ra+Rb) or (Ra)(Rb) indicate the address Ra + Rb, used by indexed
|
||
|
loads or stores. Both forms are accepted. When used with an update then the base register
|
||
|
is updated by the value in the index register.
|
||
|
|
||
|
Examples:
|
||
|
MOVD (R3), R4 <=> ld r4,0(r3)
|
||
|
MOVW (R3), R4 <=> lwa r4,0(r3)
|
||
|
MOVWZU 4(R3), R4 <=> lwzu r4,4(r3)
|
||
|
MOVWZ (R3+R5), R4 <=> lwzx r4,r3,r5
|
||
|
MOVHZ (R3), R4 <=> lhz r4,0(r3)
|
||
|
MOVHU 2(R3), R4 <=> lhau r4,2(r3)
|
||
|
MOVBZ (R3), R4 <=> lbz r4,0(r3)
|
||
|
|
||
|
MOVD R4,(R3) <=> std r4,0(r3)
|
||
|
MOVW R4,(R3) <=> stw r4,0(r3)
|
||
|
MOVW R4,(R3+R5) <=> stwx r4,r3,r5
|
||
|
MOVWU R4,4(R3) <=> stwu r4,4(r3)
|
||
|
MOVH R4,2(R3) <=> sth r4,2(r3)
|
||
|
MOVBU R4,(R3)(R5) <=> stbux r4,r3,r5
|
||
|
|
||
|
4. Compares
|
||
|
|
||
|
When an instruction does a compare or other operation that might
|
||
|
result in a condition code, then the resulting condition is set
|
||
|
in a field of the condition register. The condition register consists
|
||
|
of 8 4-bit fields named CR0 - CR7. When a compare instruction
|
||
|
identifies a CR then the resulting condition is set in that field
|
||
|
to be read by a later branch or isel instruction. Within these fields,
|
||
|
bits are set to indicate less than, greater than, or equal conditions.
|
||
|
|
||
|
Once an instruction sets a condition, then a subsequent branch, isel or
|
||
|
other instruction can read the condition field and operate based on the
|
||
|
bit settings.
|
||
|
|
||
|
Examples:
|
||
|
CMP R3, R4 <=> cmp r3, r4 (CR0 assumed)
|
||
|
CMP R3, R4, CR1 <=> cmp cr1, r3, r4
|
||
|
|
||
|
Note that the condition register is the target operand of compare opcodes, so
|
||
|
the remaining operands are in the same order for Go asm and PPC64 asm.
|
||
|
When CR0 is used then it is implicit and does not need to be specified.
|
||
|
|
||
|
5. Branches
|
||
|
|
||
|
Many branches are represented as a form of the BC instruction. There are
|
||
|
other extended opcodes to make it easier to see what type of branch is being
|
||
|
used.
|
||
|
|
||
|
The following is a brief description of the BC instruction and its commonly
|
||
|
used operands.
|
||
|
|
||
|
BC op1, op2, op3
|
||
|
|
||
|
op1: type of branch
|
||
|
16 -> bctr (branch on ctr)
|
||
|
12 -> bcr (branch if cr bit is set)
|
||
|
8 -> bcr+bctr (branch on ctr and cr values)
|
||
|
4 -> bcr != 0 (branch if specified cr bit is not set)
|
||
|
|
||
|
There are more combinations but these are the most common.
|
||
|
|
||
|
op2: condition register field and condition bit
|
||
|
|
||
|
This contains an immediate value indicating which condition field
|
||
|
to read and what bits to test. Each field is 4 bits long with CR0
|
||
|
at bit 0, CR1 at bit 4, etc. The value is computed as 4*CR+condition
|
||
|
with these condition values:
|
||
|
|
||
|
0 -> LT
|
||
|
1 -> GT
|
||
|
2 -> EQ
|
||
|
3 -> OVG
|
||
|
|
||
|
Thus 0 means test CR0 for LT, 5 means CR1 for GT, 30 means CR7 for EQ.
|
||
|
|
||
|
op3: branch target
|
||
|
|
||
|
Examples:
|
||
|
|
||
|
BC 12, 0, target <=> blt cr0, target
|
||
|
BC 12, 2, target <=> beq cr0, target
|
||
|
BC 12, 5, target <=> bgt cr1, target
|
||
|
BC 12, 30, target <=> beq cr7, target
|
||
|
BC 4, 6, target <=> bne cr1, target
|
||
|
BC 4, 1, target <=> ble cr1, target
|
||
|
|
||
|
The following extended opcodes are available for ease of use and readability:
|
||
|
|
||
|
BNE CR2, target <=> bne cr2, target
|
||
|
BEQ CR4, target <=> beq cr4, target
|
||
|
BLT target <=> blt target (cr0 default)
|
||
|
BGE CR7, target <=> bge cr7, target
|
||
|
|
||
|
Refer to the ISA for more information on additional values for the BC instruction,
|
||
|
how to handle OVG information, and much more.
|
||
|
|
||
|
5. Align directive
|
||
|
|
||
|
Starting with Go 1.12, Go asm supports the PCALIGN directive, which indicates
|
||
|
that the next instruction should be aligned to the specified value. Currently
|
||
|
8 and 16 are the only supported values, and a maximum of 2 NOPs will be added
|
||
|
to align the code. That means in the case where the code is aligned to 4 but
|
||
|
PCALIGN $16 is at that location, the code will only be aligned to 8 to avoid
|
||
|
adding 3 NOPs.
|
||
|
|
||
|
The purpose of this directive is to improve performance for cases like loops
|
||
|
where better alignment (8 or 16 instead of 4) might be helpful. This directive
|
||
|
exists in PPC64 assembler and is frequently used by PPC64 assembler writers.
|
||
|
|
||
|
PCALIGN $16
|
||
|
PCALIGN $8
|
||
|
|
||
|
Functions in Go are aligned to 16 bytes, as is the case in all other compilers
|
||
|
for PPC64.
|
||
|
|
||
|
6. Shift instructions
|
||
|
|
||
|
The simple scalar shifts on PPC64 expect a shift count that fits in 5 bits for
|
||
|
32-bit values or 6 bit for 64-bit values. If the shift count is a constant value
|
||
|
greater than the max then the assembler sets it to the max for that size (31 for
|
||
|
32 bit values, 63 for 64 bit values). If the shift count is in a register, then
|
||
|
only the low 5 or 6 bits of the register will be used as the shift count. The
|
||
|
Go compiler will add appropriate code to compare the shift value to achieve the
|
||
|
the correct result, and the assembler does not add extra checking.
|
||
|
|
||
|
Examples:
|
||
|
|
||
|
SRAD $8,R3,R4 => sradi r4,r3,8
|
||
|
SRD $8,R3,R4 => rldicl r4,r3,56,8
|
||
|
SLD $8,R3,R4 => rldicr r4,r3,8,55
|
||
|
SRAW $16,R4,R5 => srawi r5,r4,16
|
||
|
SRW $40,R4,R5 => rlwinm r5,r4,0,0,31
|
||
|
SLW $12,R4,R5 => rlwinm r5,r4,12,0,19
|
||
|
|
||
|
Some non-simple shifts have operands in the Go assembly which don't map directly
|
||
|
onto operands in the PPC64 assembly. When an operand in a shift instruction in the
|
||
|
Go assembly is a bit mask, that mask is represented as a start and end bit in the
|
||
|
PPC64 assembly instead of a mask. See the ISA for more detail on these types of shifts.
|
||
|
Here are a few examples:
|
||
|
|
||
|
RLWMI $7,R3,$65535,R6 => rlwimi r6,r3,7,16,31
|
||
|
RLDMI $0,R4,$7,R6 => rldimi r6,r4,0,61
|
||
|
|
||
|
More recently, Go opcodes were added which map directly onto the PPC64 opcodes. It is
|
||
|
recommended to use the newer opcodes to avoid confusion.
|
||
|
|
||
|
RLDICL $0,R4,$15,R6 => rldicl r6,r4,0,15
|
||
|
RLDICR $0,R4,$15,R6 => rldicr r6.r4,0,15
|
||
|
|
||
|
Register naming
|
||
|
|
||
|
1. Special register usage in Go asm
|
||
|
|
||
|
The following registers should not be modified by user Go assembler code.
|
||
|
|
||
|
R0: Go code expects this register to contain the value 0.
|
||
|
R1: Stack pointer
|
||
|
R2: TOC pointer when compiled with -shared or -dynlink (a.k.a position independent code)
|
||
|
R13: TLS pointer
|
||
|
R30: g (goroutine)
|
||
|
|
||
|
Register names:
|
||
|
|
||
|
Rn is used for general purpose registers. (0-31)
|
||
|
Fn is used for floating point registers. (0-31)
|
||
|
Vn is used for vector registers. Slot 0 of Vn overlaps with Fn. (0-31)
|
||
|
VSn is used for vector-scalar registers. V0-V31 overlap with VS32-VS63. (0-63)
|
||
|
CTR represents the count register.
|
||
|
LR represents the link register.
|
||
|
|
||
|
*/
|
||
|
package ppc64
|